Суич, тип | Fixed Port |
---|---|
Общ брой портове | 48 |
Основни портове, тип | 10/100/1000Base-T |
Uplink портове | 4x SFP |
Управление | Web UI via Cisco Configuration Professional; CLI using a Telnet or Secure Shell (SSH) client over Bluetooth. The GUI can be accessed over Bluetooth with a browser. Single IP Management. Network management |
Fans | Compact fanless |
Захранване | Single fixed power supply. Models have external power supply. Use the supplied AC power cord to connect the AC power connector to an AC power outlet. |
Routing | Static |
Памет (Flash, RAM) | 512MB DRAM, 256 MB Flash memory |
Капацитет за маршрутизиране/превключване, Gbps | 10/20 Gbps (Forwarding/Switching) |
Пропускателна способност, Mpps | 14.88 Mpps |
MAC адреси | 15 360 |
VLAN (брой, стандарти) | Maximum active: 256; IDs available: 4094 |
QoS | Up to 8 egress queues and 2 thresholds per port, Ingress policing, QoS through DSCP mapping and filtering, QoS through traffic classification, Trust boundary, AutoQoS, Shaped Round Robin (SRR) scheduling and Weighted Tail Drop (WTD), 802.1p CoS |
L2 мрежови стандарти | 802.1D STP, 802.1p CoS Prioritization, 802.1Q VLAN, 802.1s, 802.1w, 802.1X, 802.1ab LLDP, BT v4.0, 802.3ad, 802.3af, 802.3ah (100BASE-X single/multimode fiber only), 802.3x full duplex, 802.3, 802.3u, 802.3ab, 802.3z, RMON, SNMP, 802.3az, 802.3ae |
IPv6 functionality | IPv6 routing, Access Control Lists (ACLS) |
Сигурност | 802.1X, Authentication, ACLS, Port-based ACLs, SSH, Kerberos, and SNMP v3, SPAN, TACACS+ and RADIUS authentication, MAC address notification, MAC Authentication Bypass (MAB), BPDU Guard, IP Source Guard, SSH v2, STRG, IGMP |
Размери (Ш, Д, В), mm | 444.5 x 272.5 x 43.9 |
Опция за монтаж | Rackmount |
Други | USB mini-B port, USB-A port for storage and Bluetooth console |
Cisco Catalyst 1000 48port GE, 4x1G S...
Серия | Cisco 1100 |
---|---|
Интегрирани WAN портове | 1x10/100Base-TX, 1x10/100/1000Base-T |
Модулни LAN портове | 4x10/100/1000Base-T |
SFP базирани портове | 1x GE/SFP combo |
Брой EHWIC слотове | No |
WLAN стандарт | No |
Сигурност | Integrated application inspection firewall, High-performance VPNs: DMVPN, FlexVPN, GETVPN; Encrypted Traffic Analytics (ETA); Data privacy through high-speed IP Security (IPsec) 3DES and AES |
Глас | Remotely initiated data callback using voice or Short Message Service (SMS) |
Памет DRAM вградена/ max | 4GB |
Памет Flash вградена/ mах | 4GB |
USB портове | 1x USB 3.0 Type A host port |
Размери (Ш, Д, В), mm | 323 x 230 x 42 |
Допълнителна информация | 2x PoE, 1x PoE+ |
Cisco ISR 1100 4 Ports Dual GE WAN Et...
№ C9115AXI-EWC-E
Аксес-пойнт
Cisco Catalyst 9115 AP, WiFi6, Internal Antenna with Embedded Wireless Controller
Скорост | 5 Gbps |
---|---|
Антена | Integrated antenna (2.4 GHz, peak gain 3 dBi, internal antenna, omnidirectional in azimuth, 5 GHz, peak gain 4 dBi, internal antenna, omnidirectional in azimuth) |
Интерфейс | 1x 100, 1000, 2500 Multigigabit Ethernet (RJ-45) - IEEE 802.3bz; Management console port (RJ-45); USB 2.0 (enabled via future software) |
Стандарти | 802.11a/b/g/n/ac/ax |
Сигурност | 802.11i, Wi-Fi Protected Access 2 (WPA2), WPA, 802.1X, Advanced Encryption Standard (AES), EAP-Transport Layer Security (TLS), EAP-Tunneled TLS (TTLS), PEAP, EAP-FAST, EAP-GTC, EAP-SIM |
Захранване | 802.3at Power over Ethernet Plus (PoE+), 802.3bt Cisco Universal PoE (Cisco UPOE+, Cisco UPOE) |
Управление | Cisco DNA Center 1.3.2, integrated WebUI, mobile app, and third party (open standards APIs) |
Други | Number of radios: Three ( 2.4GHz, 5GHz, BLE), Channel width: 20 MHz (2.4 GHz); 20/40/80/160 MHz (5 GHz), Concurrent MU-MIMO: 4 |
Cisco Catalyst 9115 AP, WiFi6, Intern...
Скорост | 1000 Mbps |
---|---|
Антена | Integrated antenna (2.4 GHz: Peak gain 4 dBi, internal antenna, omnidirectional in azimuth, 5 GHz: Peak gain 5 dBi, internal antenna, omnidirectional in azimuth) |
Интерфейс | 1x 10/100/1000 Base-T (Ethernet) Uplink Interface; Management console port (RJ-45) |
Стандарти | 802.11a/b/g/n/ac/ax; IEEE 802.3ab, IEEE 802.3af/at, IEEE 802.11h, 802.11d |
Сигурност | 802.11i, Wi-Fi Protected Access 2 (WPA2), WPA3, 802.1X, Advanced Encryption Standard (AES); EAP-Transport Layer Security (TLS); EAP-Flexible Authentication via Secure Tunneling (EAP-FAST) |
Захранване | 802.3at Power over Ethernet Plus (PoE+), Cisco Universal PoE (Cisco UPOE) |
Управление | Management console port (RJ-45) |
Други | + with embedded wireless controller |
Cisco Embedded Wireless Controller on...
Серия | Cisco 4000 |
---|---|
Интегрирани WAN портове | 3х10/100/1000Base-T |
Модулни LAN портове | 40 |
SFP базирани портове | 2 x SFP |
Брой EHWIC слотове | 2 x NIM |
Модул интегрирани услуги | 1 x ISC |
Мрежови слот NM/SM | 1 x single-wide enhanced service-module slots |
WLAN стандарт | No |
IPSec VPN тунели | FlexVPN, Easy VPN remote server, Enhanced Easy VPN, Dynamic Multipoint VPN (DMVPN), Group Encrypted Transport VPN (GET VPN), V3PN, MPLS VPN |
Сигурност | Zone-based firewall and NAT services, Hardware VPN acceleration (DES, 3DES, AES), IPSEC VPN, Intrusion prevention, Anomaly Detection and Machine Learning, Network foundation protection, Cisco Umbrella Branch, Cisco Cloud Web Security, Cisco TrustSec |
Глас | Integrated Services Card natively supports the new Cisco High-Density Packet Voice Digital Signal Processor Modules (PVDM4s), providing greater-density rich-media voice. |
Памет DRAM вградена/ max | 4GB/ 16GB |
Памет Flash вградена/ mах | 4GB/ 16GB |
USB портове | 1 x USB 2.0 |
Размери (Ш, Д, В), mm | 438 x 438 x 45, Rack height 1U |
Допълнителна информация | IPv4 routing protocols: RIP v1/v2, EIGRP, OSPF, BGP, PBR, PfR; IPv6 routing protocols: EIGRP, RIP, OSPFv3, IS-IS, BGP and PBR |
Cisco ISR 4331 (3GE, 2NIM, 1SM, 4G FL...
Суич, тип | Fixed Port |
---|---|
Общ брой портове | 24 |
Основни портове, тип | 10/100/1000Base-T |
Uplink портове | 4x SFP |
Управление | Web UI via Cisco Configuration Professional; CLI using a Telnet or Secure Shell (SSH) client over Bluetooth. The GUI can be accessed over Bluetooth with a browser. Single IP Management. Network management |
Fans | Compact fanless |
Захранване | Single fixed power supply. Models have external power supply. Use the supplied AC power cord to connect the AC power connector to an AC power outlet. |
Routing | Static |
Памет (Flash, RAM) | 512MB DRAM, 256 MB Flash memory |
Капацитет за маршрутизиране/превключване, Gbps | 10/20 Gbps (Forwarding/Switching) |
Пропускателна способност, Mpps | 14.88 Mpps |
MAC адреси | 15 360 |
VLAN (брой, стандарти) | Maximum active: 256; IDs available: 4094 |
QoS | Up to 8 egress queues and 2 thresholds per port, Ingress policing, QoS through DSCP mapping and filtering, QoS through traffic classification, Trust boundary, AutoQoS, Shaped Round Robin (SRR) scheduling and Weighted Tail Drop (WTD), 802.1p CoS |
L2 мрежови стандарти | 802.1D STP, 802.1p CoS Prioritization, 802.1Q VLAN, 802.1s, 802.1w, 802.1X, 802.1ab LLDP, BT v4.0, 802.3ad, 802.3af, 802.3ah (100BASE-X single/multimode fiber only), 802.3x full duplex, 802.3, 802.3u, 802.3ab, 802.3z, RMON, SNMP, 802.3az, 802.3ae |
IPv6 functionality | IPv6 routing, Access Control Lists (ACLS) |
Сигурност | 802.1X, Authentication, ACLS, Port-based ACLs, SSH, Kerberos, and SNMP v3, SPAN, TACACS+ and RADIUS authentication, MAC address notification, MAC Authentication Bypass (MAB), BPDU Guard, IP Source Guard, SSH v2, STRG, IGMP |
Размери (Ш, Д, В), mm | 444.5 x 240 x 43.9 |
Опция за монтаж | Rackmount |
Други | USB mini-B port, USB-A port for storage and Bluetooth console |
Cisco Catalyst 1000 24port GE, 4x1G S...
№ AIR-AP1832I-E-K9C
Аксес-пойнт
Cisco Aironet 1800, 802.11ac Wave 2; 3x3:2SS; Int Ant; E Reg Domain (Config)
Скорост | 867 Mbps |
---|---|
Антена | Integrated antenna: 2.4 GHz, gain 3 dBi, internal omni, horizontal beamwidth 360°; 5 GHz, gain 5 dBi, internal omni, horizontal beamwidth 360° |
Интерфейс | 1x10/100/1000BASE-T Ethernet (RJ-45, PoE), USB 2.0 |
Стандарти | 802.11a, 802.11b, 802.11g, 802.11n, 802.11ac, 802.3af, 802.3at, 802.11h, 802.11d, 802.11i, 802.1x |
Сигурност | 802.11i, Wi-Fi Protected Access 2 (WPA2), WPA; 802.1X; Advanced Encryption Standards (AES), Temporal Key Integrity Protocol (TKIP) |
Захранване | Power Supply and Power Injector: 100 to 240 VAC; 50 to 60 Hz; Powering options: 802.3af/ 802.3at, Enhanced PoE, Cisco local power supply AIR-PWR-C=, Cisco power injector AIR-PWRINJ5= (Note: This injector supports 802.3af only) |
Управление | 1 x management - console - RJ-45 |
Други | Note: If 802.3af PoE is the source of power, the USB port is disabled. |
Cisco Aironet 1800, 802.11ac Wave 2; ...
№ C9120AXI-EWC-E
Аксес-пойнт
Cisco Catalyst 9120 AP, WiFi6, Internal Antenna with Embedded Wireless Controller
Скорост | uplink speeds of 2.5 Gbps, in addition to 100 Mbps and 1 Gbps |
---|---|
Антена | Integrated antenna - Flexible radio (either on 2.4 GHz or on 5 GHz), Dedicated 5-GHz radio |
Интерфейс | 1x 100, 1000, 2500 Multigigabit Ethernet (RJ-45) – IEEE 802.3bz, Management console port (RJ-45), USB 2.0 @ 3.75W (enabled via future software) |
Стандарти | IEEE 802.3; IEEE 802.3ab, IEEE 802.3af/at, IEEE 802.11 a/b/g/n/ac/ax, IEEE 802.11h, 802.11d |
Сигурност | 802.11i, Wi-Fi Protected Access 3 (WPA3), WPA2, WPA, 802.1X, Advanced Encryption Standard (AES); AP-Transport Layer Security (TLS) |
Захранване | 802.3at (PoE+); 4 x 4 (2.4/ 5-GHz radio), 2.5G Link speed, 25.5W LLDP |
Управление | Cisco DNA Center 1.3.2, integrated WebUI, mobile app, and third party (open standards APIs) |
Други | Concurrent MU-MIMO: 4 |
Cisco Catalyst 9120 AP, WiFi6, Intern...
Суич, тип | Fixed Port |
---|---|
Общ брой портове | 48 |
Основни портове, тип | 48x10/100/1000Base-T |
Power Over Ethernet (PoE) | IEEE 802.3at PoE+ Standard. Available PoE Power: 437W |
Uplink портове | 0 |
Свободни (10GB) слотове | 1 open module slot: Support four optional uplink modules (C9300-NM-4G, C9300-NM-8X, C9300-NM-2Q, C9300-NM-4M). Also supported 3850 network modules (C3850-NM-4-1G, C3850-NM-2-10G, C3850-NM-4-10G). |
Управление | SNMPv1, SNMPv2c, and SNMPv3; RMON I and II standards; Internet Group Management Protocol (IGMP); CLI; TCP; UDP |
Stackable | Cisco StackWise-480 stacking ports: copper-based Cisco StackWise cabling |
Fans | Three field-replaceable fans |
Захранване | Dual redundant power supplies, Default power supply: PWR-C1-715WAC |
Routing | Layer 3 Advanced |
Памет (Flash, RAM) | Flash memory: 16 GB; RAM: 8 GB DRAM |
Капацитет за маршрутизиране/превключване, Gbps | 256 Gbps |
Пропускателна способност, Mpps | 190.48 Mpps |
MAC адреси | 32000 MAC address table size |
VLAN (брой, стандарти) | VLAN IDs: 4000; IEEE 802.1Q VLAN |
QoS | Granular wireless bandwidth management and fair sharing,802.1p Class of Service (CoS) and Differentiated Services Code Point (DSCP) field classification,Shaped Round Robin (SRR) scheduling,Committed Information Rate (CIR), and eight egress queues per port |
L2 мрежови стандарти | IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3bz, IEEE 802.3ad, IEEE 802.3af, IEEE 802.3at, IEEE 802.1D, IEEE 802.1p, IEEE 802.1Q, IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.1x-Rev, IEEE 802.3x, IEEE 802.1AE |
L3 мрежови стандарти | IP unicast routing protocols: Static, Routing Information Protocol Version 1 [RIPv1], and RIPv2, RIPng, Open Shortest Path First [OSPF] |
IPv6 functionality | IPv6 routing; IPv6 addressing; Dual-stack support for IPv4/IPv6 and dynamic hardware forwarding table allocations, for ease of IPv4-to-IPv6 migration; IPv6 support in hardware, providing wire-rate forwarding for IPv6 networks |
Сигурност | Encrypted Traffic Analytics (ETA), AES-256 MACsec encryption, Trustworthy systems built with Cisco Trust Anchor Technologies (Image signing, Secure Boot, Cisco Trust Anchor module) |
Размери (Ш, Д, В), mm | 445 x 445 x 44 |
Опция за монтаж | Rackmount |
Други | Задължителен е минимум 3-годишен лиценз DNA Essentials. |
Cisco Catalyst 9300 48-port PoE+, Net...
Суич, тип | Fixed Port |
---|---|
Общ брой портове | 16 |
Основни портове, тип | 10/100/1000Base-T |
Power Over Ethernet (PoE) | Support both IEEE 802.3af PoE and IEEE 802.3at PoE+; 30W for any 4 ports or 15W for any 8 ports; PoE power budget: 120W |
Uplink портове | 2x SFP |
Управление | Web UI via Cisco Configuration Professional; CLI using a Telnet or Secure Shell (SSH) client over Bluetooth. The GUI can be accessed over Bluetooth with a browser. Single IP Management. Network management |
Fans | Compact fanless |
Захранване | Single fixed power supply. Models have external power supply. Use the supplied AC power cord to connect the AC power connector to an AC power outlet. |
Routing | Static |
Памет (Flash, RAM) | 512MB DRAM, 256 MB Flash memory |
Капацитет за маршрутизиране/превключване, Gbps | 10/20 Gbps (Forwarding/Switching) |
Пропускателна способност, Mpps | 14.88 Mpps |
MAC адреси | 15 360 |
VLAN (брой, стандарти) | Maximum active: 256; IDs available: 4094 |
QoS | Up to 8 egress queues and 2 thresholds per port, Ingress policing, QoS through DSCP mapping and filtering, QoS through traffic classification, Trust boundary, AutoQoS, Shaped Round Robin (SRR) scheduling and Weighted Tail Drop (WTD), 802.1p CoS |
L2 мрежови стандарти | 802.1D STP, 802.1p CoS Prioritization, 802.1Q VLAN, 802.1s, 802.1w, 802.1X, 802.1ab LLDP, BT v4.0, 802.3ad, 802.3af, 802.3ah (100BASE-X single/multimode fiber only), 802.3x full duplex, 802.3, 802.3u, 802.3ab, 802.3z, RMON, SNMP, 802.3az, 802.3ae |
IPv6 functionality | IPv6 routing, Access Control Lists (ACLS) |
Сигурност | 802.1X, Authentication, ACLS, Port-based ACLs, SSH, Kerberos, and SNMP v3, SPAN, TACACS+ and RADIUS authentication, MAC address notification, MAC Authentication Bypass (MAB), BPDU Guard, IP Source Guard, SSH v2, STRG, IGMP |
Размери (Ш, Д, В), mm | 268.2 x 296.9 x 43.9 |
Опция за монтаж | Rackmount |
Други | USB mini-B port, USB-A port for storage and Bluetooth console |
Cisco Catalyst 1000 16port GE, POE, 2...
Серия | Cisco 1100 |
---|---|
Интегрирани WAN портове | 1x10/100Base-TX, 1x10/100/1000Base-T |
Модулни LAN портове | 8x10/100/1000Base-T |
SFP базирани портове | 1x GE/SFP combo |
Брой EHWIC слотове | No |
WLAN стандарт | No |
Сигурност | Integrated application inspection firewall, High-performance VPNs: DMVPN, FlexVPN, GETVPN; Encrypted Traffic Analytics (ETA); Data privacy through high-speed IP Security (IPsec) 3DES and AES |
Глас | Remotely initiated data callback using voice or Short Message Service (SMS) |
Памет DRAM вградена/ max | 4GB |
Памет Flash вградена/ mах | 4GB |
USB портове | 1x USB 3.0 Type A host port |
Размери (Ш, Д, В), mm | 323 x 230 x 42 |
Допълнителна информация | 4x PoE, 2x PoE+; 2x2 MIMO |
Cisco ISR 1100 8 Ports Dual GE WAN Et...
Суич, тип | Fixed Port |
---|---|
Общ брой портове | 24 |
Основни портове, тип | 24x10/100/1000Base-T |
Power Over Ethernet (PoE) | No |
Uplink портове | 0 |
Свободни (10GB) слотове | Modular uplink options (C9200-NM-4G, C9200-NM-4X) |
Управление | SNMPv1, SNMPv2c, and SNMPv3; RMON I and II standards; Internet Group Management Protocol (IGMP); CLI; TCP; UDP |
Stackable | Cisco StackWise-160 stacking ports: copper-based Cisco StackWise cabling, Stacking hardware (C9200-STACK-KIT=), Supported stack members: Other C9200 models with same license level (8 Number of members) |
Fans | Field-Replaceable Units (FRU) redundant |
Захранване | Dual field-replaceable power supplies, Default primary AC power supply: PWR-C5-125WAC |
Routing | Layer 3 Advanced |
Памет (Flash, RAM) | Flash memory: 4 GB; RAM: 4 GB DRAM |
Капацитет за маршрутизиране/превключване, Gbps | 128 Gbps |
Пропускателна способност, Mpps | 190.4 Mpps |
MAC адреси | 32000 MAC address |
VLAN (брой, стандарти) | VLAN IDs: 4096; IEEE 802.1Q VLAN |
QoS | Granular wireless bandwidth management and fair sharing,802.1p Class of Service (CoS) and Differentiated Services Code Point (DSCP) field classification,Shaped Round Robin (SRR) scheduling,Committed Information Rate (CIR), and eight egress queues per port |
L2 мрежови стандарти | IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3bz, IEEE 802.3ad, IEEE 802.1D, IEEE 802.1p, IEEE 802.1Q, IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.1x-Rev, IEEE 802.3x |
L3 мрежови стандарти | IP unicast routing protocols: Static, Routing Information Protocol Version 1 [RIPv1], and RIPv2, RIPng, Open Shortest Path First [OSPF] |
IPv6 functionality | IPv6 routing (using OSPFv3 and EIGRPv6) is supported in hardware for maximum performance; IPv6 addressing is supported on interfaces with appropriate show commands for monitoring and troubleshooting |
Сигурност | Enhanced security with AES-128 MACsec encryption, policy-based segmentation, and trustworthy systems |
Размери (Ш, Д, В), mm | 445 x 350 x 44 |
Опция за монтаж | Rackmount |
Други | Задължителен е минимум 3-годишен лиценз DNA Essentials. |
Cisco Catalyst 9200 24-port Data Swit...
Суич, тип | Fixed Port |
---|---|
Общ брой портове | 16 |
Основни портове, тип | 10/100/1000Base-T |
Uplink портове | 2x SFP |
Управление | Web UI via Cisco Configuration Professional; CLI using a Telnet or Secure Shell (SSH) client over Bluetooth. The GUI can be accessed over Bluetooth with a browser. Single IP Management. Network management |
Fans | Compact fanless |
Захранване | Single fixed power supply. Models have external power supply. Use the supplied AC power cord to connect the AC power connector to an AC power outlet. |
Routing | Static |
Памет (Flash, RAM) | 512MB DRAM, 256 MB Flash memory |
Капацитет за маршрутизиране/превключване, Gbps | 10/20 Gbps (Forwarding/Switching) |
Пропускателна способност, Mpps | 14.88 Mpps |
MAC адреси | 15 360 |
VLAN (брой, стандарти) | Maximum active: 256; IDs available: 4094 |
QoS | Up to 8 egress queues and 2 thresholds per port, Ingress policing, QoS through DSCP mapping and filtering, QoS through traffic classification, Trust boundary, AutoQoS, Shaped Round Robin (SRR) scheduling and Weighted Tail Drop (WTD), 802.1p CoS |
L2 мрежови стандарти | 802.1D STP, 802.1p CoS Prioritization, 802.1Q VLAN, 802.1s, 802.1w, 802.1X, 802.1ab LLDP, BT v4.0, 802.3ad, 802.3af, 802.3ah (100BASE-X single/multimode fiber only), 802.3x full duplex, 802.3, 802.3u, 802.3ab, 802.3z, RMON, SNMP, 802.3az, 802.3ae |
IPv6 functionality | IPv6 routing, Access Control Lists (ACLS) |
Сигурност | 802.1X, Authentication, ACLS, Port-based ACLs, SSH, Kerberos, and SNMP v3, SPAN, TACACS+ and RADIUS authentication, MAC address notification, MAC Authentication Bypass (MAB), BPDU Guard, IP Source Guard, SSH v2, STRG, IGMP |
Размери (Ш, Д, В), mm | 268.2 x 271.5 x 43.9 |
Опция за монтаж | Rackmount |
Други | USB mini-B port, USB-A port for storage and Bluetooth console |
Cisco Catalyst 1000 16port GE, 2x1G S...
Суич, тип | Fixed Port |
---|---|
Общ брой портове | 48 |
Основни портове, тип | 48x10/100/1000Base-T |
Power Over Ethernet (PoE) | No |
Uplink портове | 0 |
Свободни (10GB) слотове | 1 open module slot: Support four optional uplink modules (C9300-NM-4G, C9300-NM-8X, C9300-NM-2Q, C9300-NM-4M). Also supported 3850 network modules (C3850-NM-4-1G, C3850-NM-2-10G, C3850-NM-4-10G). |
Управление | SNMPv1, SNMPv2c, and SNMPv3; RMON I and II standards; Internet Group Management Protocol (IGMP); CLI; TCP; UDP |
Stackable | Cisco StackWise-480 stacking ports: copper-based Cisco StackWise cabling |
Fans | Three field-replaceable fans |
Захранване | Dual redundant power supplies, Default power supply: PWR-C1-350WAC |
Routing | Layer 3 Advanced |
Памет (Flash, RAM) | Flash memory: 16 GB; RAM: 8 GB DRAM |
Капацитет за маршрутизиране/превключване, Gbps | 256 Gbps |
Пропускателна способност, Mpps | 190.48 Mpps |
MAC адреси | 32000 MAC address table size |
VLAN (брой, стандарти) | VLAN IDs: 4000; IEEE 802.1Q VLAN |
QoS | Granular wireless bandwidth management and fair sharing,802.1p Class of Service (CoS) and Differentiated Services Code Point (DSCP) field classification,Shaped Round Robin (SRR) scheduling,Committed Information Rate (CIR), and eight egress queues per port |
L2 мрежови стандарти | IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3bz, IEEE 802.3ad, IEEE 802.1D, IEEE 802.1p, IEEE 802.1Q, IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.1x-Rev, IEEE 802.3x, IEEE 802.1AE |
L3 мрежови стандарти | IP unicast routing protocols: Static, Routing Information Protocol Version 1 [RIPv1], and RIPv2, RIPng, Open Shortest Path First [OSPF] |
IPv6 functionality | IPv6 routing; IPv6 addressing; Dual-stack support for IPv4/IPv6 and dynamic hardware forwarding table allocations, for ease of IPv4-to-IPv6 migration; IPv6 support in hardware, providing wire-rate forwarding for IPv6 networks |
Сигурност | Encrypted Traffic Analytics (ETA), AES-256 MACsec encryption, Trustworthy systems built with Cisco Trust Anchor Technologies (Image signing, Secure Boot, Cisco Trust Anchor module) |
Размери (Ш, Д, В), mm | 445 x 445 x 44 |
Опция за монтаж | Rackmount |
Други | Задължителен е минимум 3-годишен лиценз DNA Essentials. |
Cisco Catalyst 9300 48-port data only...
Суич, тип | Fixed Port |
---|---|
Общ брой портове | 48 |
Основни портове, тип | 10/100/1000Base-T |
Power Over Ethernet (PoE) | Support both IEEE 802.3af PoE and IEEE 802.3at PoE+; 30W for any 12 ports or 15W for 24 ports; PoE power budget: 370W |
Uplink портове | 4x 10G SFP+ |
Управление | Web UI via Cisco Configuration Professional; CLI using a Telnet or Secure Shell (SSH) client over Bluetooth. The GUI can be accessed over Bluetooth with a browser. Single IP Management. Network management |
Fans | yes |
Захранване | Single fixed power supply. Models have external power supply. Use the supplied AC power cord to connect the AC power connector to an AC power outlet. |
Routing | Static |
Памет (Flash, RAM) | 512MB DRAM, 256 MB Flash memory |
Капацитет за маршрутизиране/превключване, Gbps | 10/20 Gbps (Forwarding/Switching) |
Пропускателна способност, Mpps | 14.88 Mpps |
MAC адреси | 15 360 |
VLAN (брой, стандарти) | Maximum active: 256; IDs available: 4094 |
QoS | Up to 8 egress queues and 2 thresholds per port, Ingress policing, QoS through DSCP mapping and filtering, QoS through traffic classification, Trust boundary, AutoQoS, Shaped Round Robin (SRR) scheduling and Weighted Tail Drop (WTD), 802.1p CoS |
L2 мрежови стандарти | 802.1D STP, 802.1p CoS Prioritization, 802.1Q VLAN, 802.1s, 802.1w, 802.1X, 802.1ab LLDP, BT v4.0, 802.3ad, 802.3af, 802.3ah (100BASE-X single/multimode fiber only), 802.3x full duplex, 802.3, 802.3u, 802.3ab, 802.3z, RMON, SNMP, 802.3az, 802.3ae |
IPv6 functionality | IPv6 routing, Access Control Lists (ACLS) |
Сигурност | 802.1X, Authentication, ACLS, Port-based ACLs, SSH, Kerberos, and SNMP v3, SPAN, TACACS+ and RADIUS authentication, MAC address notification, MAC Authentication Bypass (MAB), BPDU Guard, IP Source Guard, SSH v2, STRG, IGMP |
Размери (Ш, Д, В), mm | 444.5 x 350 x 43.9 |
Опция за монтаж | Rackmount |
Други | USB mini-B port, USB-A port for storage and Bluetooth console |
Cisco Catalyst 1000 48 port GE, POE, ...
Суич, тип | Fixed Port |
---|---|
Общ брой портове | 24 |
Основни портове, тип | 10/100/1000Base-T |
Power Over Ethernet (PoE) | Support both IEEE 802.3af PoE and IEEE 802.3at PoE+; 30W for any 6 ports or 15W for any 13 ports; PoE power budget: 195W |
Uplink портове | 4x SFP |
Управление | Web UI via Cisco Configuration Professional; CLI using a Telnet or Secure Shell (SSH) client over Bluetooth. The GUI can be accessed over Bluetooth with a browser. Single IP Management. Network management |
Fans | Compact fanless |
Захранване | Single fixed power supply. Models have external power supply. Use the supplied AC power cord to connect the AC power connector to an AC power outlet. |
Routing | Static |
Памет (Flash, RAM) | 512MB DRAM, 256 MB Flash memory |
Капацитет за маршрутизиране/превключване, Gbps | 10/20 Gbps (Forwarding/Switching) |
Пропускателна способност, Mpps | 14.88 Mpps |
MAC адреси | 15 360 |
VLAN (брой, стандарти) | Maximum active: 256; IDs available: 4094 |
QoS | Up to 8 egress queues and 2 thresholds per port, Ingress policing, QoS through DSCP mapping and filtering, QoS through traffic classification, Trust boundary, AutoQoS, Shaped Round Robin (SRR) scheduling and Weighted Tail Drop (WTD), 802.1p CoS |
L2 мрежови стандарти | 802.1D STP, 802.1p CoS Prioritization, 802.1Q VLAN, 802.1s, 802.1w, 802.1X, 802.1ab LLDP, BT v4.0, 802.3ad, 802.3af, 802.3ah (100BASE-X single/multimode fiber only), 802.3x full duplex, 802.3, 802.3u, 802.3ab, 802.3z, RMON, SNMP, 802.3az, 802.3ae |
IPv6 functionality | IPv6 routing, Access Control Lists (ACLS) |
Сигурност | 802.1X, Authentication, ACLS, Port-based ACLs, SSH, Kerberos, and SNMP v3, SPAN, TACACS+ and RADIUS authentication, MAC address notification, MAC Authentication Bypass (MAB), BPDU Guard, IP Source Guard, SSH v2, STRG, IGMP |
Размери (Ш, Д, В), mm | 444.5 x 298.7 x 43.9 |
Опция за монтаж | Rackmount |
Други | USB mini-B port, USB-A port for storage and Bluetooth console |
Cisco Catalyst 1000 24port GE, POE, 4...
Х-ка 1 | Device Type: SFP+ transceiver module supports a link length of 10 kilometers on standard Single-Mode Fiber (SMF, G.652); does not support FCoE |
---|---|
Х-ка 2 | Cabling Type: 10GBase-LR |
Х-ка 3 | Data Transfer Rate : 10 Gbps |
Х-ка 4 | Max Transfer Distance : 10 km |
Х-ка 5 | Optical Wave Length : 1310 nm; Transmit and Receive Wavelength (nm): 1260 to 1355 |
Х-ка 6 | Dimensions (WxDxH): 13.4 x 56.5 x 8.5 mm |
Cisco 10GBASE-LR SFP Module, Enterpri...
№ N9K-C93180YC-FX
Комутатор
Cisco Nexus 9300 with 48p 1/10G/25G SFP and 6p 40G/100G QSFP28, MACsec, and Unified Ports capable
Суич, тип | Fixed Port |
---|---|
Общ брой портове | 54 |
Основни портове, тип | 48 x 10/25-Gbps and 6 x 40/100-Gbps QSFP28 ports |
Свободни (10GB) слотове | No |
Управление | Intelligent Buffer Management; Management ports: 1 RJ-45 port L1 and L2 ports are unused |
Fans | Optional fan module with fan slots (up to 4) |
Захранване | Hot-swappable PSU (up to 2); 500W AC, 930W DC, or 1200W HVAC/HVDC |
Routing | Layer 3 RIP (RIPv2, EIGRP, IPv4/IPv6 routing, PIM-SM, SSM, MSDP) |
Памет (Flash, RAM) | System memory: Up to 32 GB; SSD drive: 128 GB; System buffer: 40 MB |
Капацитет за маршрутизиране/превключване, Gbps | 696 Gbps |
Пропускателна способност, Mpps | 517 Mpps |
MAC адреси | 512 000 MAC address (127 VLANs out of 4096 are reserved) |
VLAN (брой, стандарти) | 4096 (127 VLANs out of 4096 are reserved); Maximum number of VLAN’s in Rapid per-VLAN Spanning Tree (RPVST) instances: 3 967 |
Сигурност | IEEE 802.1ae MAC Security (MACsec) support on all ports; Flexible forwarding tables support up to 2 million shared entries on FX models. Flexible use of TCAM space allows for custom definition of Access Control List (ACL) templates. |
Размери (Ш, Д, В), mm | 439 x 571 x 44 |
Опция за монтаж | Rackmount, 1 RU |
Други | 1x USB port; 1x RS-232 serial port |
Cisco Nexus 9300 with 48p 1/10G/25G S...
Предназначен за | Комутатори |
---|---|
Х-ка 2 | Maximum output power: 350 W |
Х-ка 3 | Input voltage and Frequency: 350 W, 100 to 240 VAC(autoranging) 50-60 Hz |
Х-ка 4 | Input current: 4–2 A |
Х-ка 5 | Output ratings: 56 V@6.25 A |