1

№ 6535EC2
Lenovo Storage V3700 V2 SFF Control Enclosure
Сторидж, типSAN
СерияV3700 V2
SAS Interface4x 12 Gb SAS host ports (Mini-SAS HD, SFF-8644)
iSCSI Interface4x 1 Gb iSCSI host ports (UTP, RJ-45) (2 ports per node canister)
Maximum Disk DrivesSFF drives: 300 GB, 600 GB, and 900 GB 15K rpm SAS HDDs; 900 GB, 1.2 TB, 1.8 TB, and 2.4 TB 10K rpm SAS HDDs; 2 TB 7.2K rpm NL SAS HDDs; 400 GB, 800 GB, 1.6 TB, and 3.2 TB SAS SSDs; 1.92 TB, 3.84 TB, 7.68 TB, and 15.36 TB read-optimized SAS SSDs
КонтролерDual controller (known as node canister) configuration
Controller cache16 GB per system (8 GB per node canister). V3700 XP is upgradeable to 32 GB (16 GB per node canister). Cache mirroring between the node canisters. Flash-backed cache protection (includes battery)
RAIDRAID 0, 1, 5, 6, and 10; Distributed RAID 5 and 6
ЗахранванеTwo redundant hot-swap 800 W AC power supplies
Maximum Raw CapacityUp to 4.055 PB (264x 15.36 TB SAS SSDs)
Поддържани операционни системиMicrosoft Windows Server 2012, 2012 R2, and 2016; Red Hat Enterprise Linux (RHEL) 6 and 7; SUSE Linux Enterprise Server (SLES) 11 and 12; VMware vSphere 5.1, 5.5, 6.0, and 6.5
Форм-фактор2U

Lenovo Storage V3700 V2 SFF Control E...

Lenovo Storage V3700 V2 SFF Control Enclosure
№ 6535EC2
№ 6535EN1
Lenovo Storage V3700 V2 LFF Expansion Enclosure
Сторидж, типSAN
СерияV3700 V2
SAS Interface4x 12 Gb SAS host ports (Mini-SAS HD, SFF-8644)
iSCSI Interface4x 1 Gb iSCSI host ports (UTP, RJ-45) (2 ports per node canister)
Maximum Disk DrivesLFF drives: 300 GB, 600 GB, and 900 GB 15K rpm SAS HDDs; 900 GB, 1.2 TB, 1.8 TB, and 2.4 TB 10K rpm SAS HDDs; 4 TB, 6 TB, 8 TB, 10 TB, and 12 TB 7.2K rpm NL SAS HDDs
КонтролерDual controller (known as node canister) configuration
Controller cache16 GB per system (8 GB per node canister). V3700 XP is upgradeable to 32 GB (16 GB per node canister). Cache mirroring between the node canisters. Flash-backed cache protection (includes battery)
RAIDRAID 0, 1, 5, 6, and 10; Distributed RAID 5 and 6
ЗахранванеTwo redundant hot-swap 800 W AC power supplies
Maximum Raw CapacityUp to 4.055 PB (264x 15.36 TB SAS SSDs)
Поддържани операционни системиMicrosoft Windows Server 2012, 2012 R2, and 2016; Red Hat Enterprise Linux (RHEL) 6 and 7; SUSE Linux Enterprise Server (SLES) 11 and 12; VMware vSphere 5.1, 5.5, 6.0, and 6.5
Форм-фактор2U

Lenovo Storage V3700 V2 LFF Expansion...

Lenovo Storage V3700 V2 LFF Expansion Enclosure
№ 6535EN1
№ 6535EN2
Lenovo Storage V3700 V2 SFF Expansion Enclosure
Сторидж, типSAN
СерияV3700 V2
SAS Interface4x 12 Gb SAS host ports (Mini-SAS HD, SFF-8644)
iSCSI Interface4x 1 Gb iSCSI host ports (UTP, RJ-45) (2 ports per node canister)
Maximum Disk DrivesSFF drives: 300 GB, 600 GB, and 900 GB 15K rpm SAS HDDs; 900 GB, 1.2 TB, 1.8 TB, and 2.4 TB 10K rpm SAS HDDs; 2 TB 7.2K rpm NL SAS HDDs; 400 GB, 800 GB, 1.6 TB, and 3.2 TB SAS SSDs; 1.92 TB, 3.84 TB, 7.68 TB, and 15.36 TB read-optimized SAS SSDs
КонтролерDual controller (known as node canister) configuration
Controller cache16 GB per system (8 GB per node canister). V3700 XP is upgradeable to 32 GB (16 GB per node canister). Cache mirroring between the node canisters. Flash-backed cache protection (includes battery)
RAIDRAID 0, 1, 5, 6, and 10; Distributed RAID 5 and 6
ЗахранванеTwo redundant hot-swap 800 W AC power supplies
Maximum Raw CapacityUp to 4.055 PB (264x 15.36 TB SAS SSDs)
Поддържани операционни системиMicrosoft Windows Server 2012, 2012 R2, and 2016; Red Hat Enterprise Linux (RHEL) 6 and 7; SUSE Linux Enterprise Server (SLES) 11 and 12; VMware vSphere 5.1, 5.5, 6.0, and 6.5
Форм-фактор2U

Lenovo Storage V3700 V2 SFF Expansion...

Lenovo Storage V3700 V2 SFF Expansion Enclosure
№ 6535EN2
1